Latest News

May 2020

 

Expervent were commissioned to replace four filter outlet exhaust stack attenuators at a major manufacturing plant in the north east of england.

 

The project was carried out over a weekend and alligned to production to allow for no down time.

 

The project included the removal of the existing corrouded exhaust stacks, replace with the new  galvansied mild steel units manufactured in house.

 

The project was delivered on time with no effect on factory production. 

April 2020

 

Expervent complete the design, manufacture & installation of a stainless steel metal spraying L.E.V dust control system to HSG258.

 

The system included the design, manufacture and installation of the dust filter unit & fan set complete with electrical controls & wiring, Supply and installation of a 1000kg parts loading rail, manufacture, supply and installation of a bespoke capture hood housed in an accoustic enclosure.

 

The accoustic enclosure was 15m x 3m x 2.5m high with 100mm thick lined wall and roof panels, complete with L.E.D lights and 1 x 1800mm access door. On completion the system was benchmark commissioned to HSG258, complete with L.E.V service report & the system L.E.V log book.

 

April 2019

Expervent complete the installation of two dust extraction systems at waste recycling plants on the Isle of Bute Scotland.

 

The systems included the installation of

cartridge filter units, manufacture and installation of a new main conveyor enclosure hood, manufacture and insatllation of bespoke dust capture hoods to conveyor systems, manufacture and installation of interconnecting ductwork and installation of a 55KW direct drive centrifugal fan unit complete with accoustic enclosure and all ancillaries. Upon completion the systems were commissioned to HSG258.

Waste Feed Hopper Enclosure Hood  & Interconnecting Dust Control Ductwork.

 

 

Accoustic Enclosure Housing 55KW Fan unit, Air Compressor & Inverter Control System

 

 

January 2019

Expervent design, manufacture and installed a new ATEX maintenance workshop within one of the largest earthmoving equipment manufacturing  plants in the uk.

 

The installation included solvent cleaning stations, ATEX lighting, heaters, & controls all of which were installed by COMPEX trained personnel.

November 2018

Expervent were commissioned to complete the installation of an odour abatement filtration system at a waste recycling plant on the Isle of Guernsey. 

 

The project included the installation of a 112 cartridge reverse pulse jet filter unit.  

March 2018

 

Expervent completed the installation of a new heat recovery ventilation system to a college in the north east of england.

 

The sytem included the supply and installation of ten lossnay heat recovery units serving ten classrooms & offices including all

interconnecting ductwork, grilles, dampers,

builders works & roof penetrations.

November 2016

Expervent are now certified manufacturers and installers of Firemac fire rated duct systems. 

 

The first of these third party certified systems has been designed, manufactured and installed in the revamped INTU Eldon Square Grey's Food Quarter - Newcastle.

September 2016

Expervent Design, Manufacture, Install and benchmark commision to HSG 258 a large chrome plating facility LEV system on Tyneside.

 

The system included 12 x bespoke designed LEV capture hoods and run standby 11kw centrifugal extraction fan units and replacement air make up system.

May 2016

Wylam Brewery is situated in Newcastles exhibition Park and is the last remaining building from the 1929 North East Coast Exhibition.

 

Expervent Designed Manufactured and installed a Kitchen ventilation system conforming to B&ES specification DW172.

March 2016

Expervent design, manufacture, install & commission a bespoke process vacuum system at the largest bakery in the UK.

 

In order to meet the clients requirement of no production down time. The system has an auto changeover Run - Standby set up to ensure the facility can maintain production requirements at all times.

January 2016

Expervent complete the installation of a turnkey HVAC and LEV Fume Control system to a specialist research laboratory in the North East of England.

 

The system includes 2 x fume cupboards, 1 x centrifugal fan unit and a temperature & humidity replacement air handling system.

Expervent Ltd.

1 Kings Court Industrial Park

Blackett Street

Jarrow

Tyne & Wear

NE32 3QS

 

Tel: 0191 489 5400

enquiries@expervent.com

Useful Links

What is a Local Exhaust Ventilation System?

Guidance on Local Exhaust Ventilation Selection

Institute of Local Exhaust Ventilation Engineers

Guidance on the Control of Substances Hazardous to Health

Chartered Institute of Building Services Engineers

Print | Sitemap
© Expervent Limited - +44 (0)191 489 5400